banner
Varcolab India Pvt Ltd

GST : 27AAJCV5431C1ZF

Auto Ranging Conductivity
Auto Ranging Conductivity

Auto Ranging Conductivity

MOQ : 1 Unit

Auto Ranging Conductivity Specification

  • Accuracy
  • 1% F.S.
  • Temperature Resistance
  • Up to 60C
  • Control Type
  • Microprocessor Based
  • Power Supply
  • AC 220V, 50 Hz or 9V DC Battery
  • Features
  • Auto range selection, temperature compensation, compact size, portable, user friendly
  • Display Type
  • Large LCD Digital Display
  • Shape
  • Rectangular
  • Type
  • Auto Ranging Conductivity Meter
  • Dimension (L*W*H)
  • 210 x 205 x 70 mm
  • Equipment Type
  • Digital Analytical Instrument
  • Equipment Materials
  • Plastic, Metal
  • Power
  • AC Adapter / Battery Operated
  • Voltage
  • 220 V (AC adapter) / 9V Battery
  • Material
  • ABS Plastic Body
  • Application
  • Measurement of electrical conductivity in solutions
  • Calibration
  • Digital, Single-point or Multi-point
  • Sample Type
  • Liquid Solutions
  • Weight
  • Approx. 1 kg
  • Measurement Range
  • 0 to 200 mS/cm (auto range)
  • Operating Temperature
  • 0-50C
  • Temperature Compensation
  • Automatic (ATC): 0-50C
  • Standard Accessories
  • Conductivity Cell, Temperature Probe, Instruction Manual, Calibration Solution
  • Cell Constant
  • K=1.0
  • Resolution
  • 0.01/0.1/1 S/cm or mS/cm (auto switch)
 

Auto Ranging Conductivity Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 1 Week
 

About Auto Ranging Conductivity



Experience commanding precision with this Elite Auto Ranging Conductivity Meter, designed for prodigious accuracy and rarefied measurement requirements. Featuring a measurement range from 0 to 200 mS/cm and automatic temperature compensation (ATC) from 0C to 50C, this digital analytical instrument ensures reliable results across diverse liquid solutions. The large digital display, microprocessor-based controls, and user-friendly interface combine to offer a hot deal on the market. ABS plastic construction, combined with portability and multi-power options, make it a top clearance choice for laboratories and industrial uses.

Elite Features & Advantages of Auto Ranging Conductivity

This auto ranging conductivity meter comes equipped with state-of-the-art automatic range selection, allowing seamless transitions between ranges for both routine and prodigious applications. Its rarefied accuracy, digital calibration (single or multi-point), and user-centered design ensure simplified operation. The compact, lightweight build enhances portability, while the commanding large LCD display provides clear, instant readings. Precision, speed, and reliability make it a preferred solution for professional analysis across laboratories and field environments.


Main Export Markets, Exchange Terms, and Order Completion

Designed for commanding presence in international markets, this auto ranging conductivity meter finds high demand in North America, Europe, Southeast Asia, and the Middle East. Shipments are efficiently managed through well-established FOB ports in India. Flexible proposal amounts and clear payment terms, including T/T and L/C, streamline the exchange process. Fast order completion ensures reliable supply, sustaining strong partnerships and customer satisfaction with every export transaction.


FAQ's of Auto Ranging Conductivity:


Q: How does automatic range selection benefit users of this conductivity meter?

A: Automatic range selection allows the instrument to seamlessly switch measurement ranges, ensuring optimal accuracy and convenience without manual intervention, ideal for diverse testing environments.

Q: What types of solutions can be measured with this auto ranging conductivity meter?

A: This device is designed for the measurement of electrical conductivity in various liquid solutions, making it suitable for laboratory, industrial, and field analyses.

Q: Where can the Auto Ranging Conductivity Meter be effectively utilized?

A: It is effective in laboratories, educational institutions, environmental agencies, and industrial settings requiring precise and reliable conductivity measurements in liquid samples.

Q: What process is involved in calibrating the meter?

A: Calibration is digital and can be performed as a single-point or multi-point process using the included calibration solution for consistent, commandingly accurate results.

Q: When should temperature compensation be used?

A: Temperature compensation is automatically applied between 0C and 50C to ensure precision in conductivity readings, particularly important when liquid sample temperatures vary.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lab Testing Equipment Category

VMD-10 Media Degasser

VMD-10 Media Degasser

Minimum Order Quantity : 1 Unit

Power Supply : AC Mains

Speed Range : 5001500 rpm

Equipment Type : Table Top

Features : Vacuum Efficient, High Chemical Resistance, Uniform Degassing, Durable Construction

Display Type : LED Digital Display

VRB-WU Bottle Rotating Apparatus

VRB-WU Bottle Rotating Apparatus

Minimum Order Quantity : 1 Unit

Power Supply : 50 Hz, Single Phase

Speed Range : 1080 RPM (adjustable)

Equipment Type : Rotating Bottle Mixer

Features : Stainless steel bottle holders, Removable trays, Adjustable speed

Display Type : Analog speed indicator

VMP-06H Peristaltic Pumps

VMP-06H Peristaltic Pumps

Minimum Order Quantity : 1 Unit

Power Supply : 210V 250V, 50/60 Hz

Speed Range : 0.1 100 rpm

Equipment Type : Peristaltic Pump

Features : Reversible direction, low maintenance, quick tubing change, high precision

Display Type : 4digit LED display

VLT-600P Leak Tester

VLT-600P Leak Tester

Minimum Order Quantity : 1 Unit

Power Supply : Single Phase

Speed Range : 0300 rpm (adjustable)

Equipment Type : Testing Equipment

Features : Digital Timer, Pressure Regulator, Compact Design, Corrosion Resistant, User Friendly Operation

Display Type : Digital LED